Planet Technology 8-Port Manual de usuario

Busca en linea o descarga Manual de usuario para Gateways / Controladores Planet Technology 8-Port. Planet Technology 8-Port User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - User’s Manual

8-Port IP Power Manager IPM-8001 IPM-8002 User’s Manual

Pagina 2 - FCC Caution:

Name Function Description LAN Ethernet (LAN) port Enables you to connect IP Power Manager to a LAN or WAN. Console Console port Enables you to con

Pagina 3

Chapter 2 Hardware Installation Before you proceed with the installation, it is necessary that you have enough information about the IP Power Manager

Pagina 4

2.3 Connecting Digital Outputs The IP Power Manager provides two digital outputs (NO by default) to which you can connect indicators or other outpu

Pagina 5 - ...15

2.5 Connecting The Console You can control the output devices and manage their power status through the console port with serial connection. Use th

Pagina 6 - Chapter 1 Introduction

- 9 - control the IP Power Manager from your PC or laptop. When the network has installed a router, you can also use your mobile phone or PDA that is

Pagina 7 - 1.4 Front and Rear Panel

Chapter 3 User Control Button You can turn on power manually for each of the eight output devices with the control buttons provided under each statu

Pagina 8 - Button Description

Chapter 4 Quick Setup When you are first time configure your IP Power Manager. You may refer to this chapter to know how to initial your IP Power Man

Pagina 9 - 1.6 Front Panel Interface

5. In default, IP Power Manager is DHCP client enables. If there is no DHCP server in your network. Please click “Set IP” button. Then enter an IP a

Pagina 11

Chapter 5 Configure With Console The IP Power Manager has provided a serial port that enables you to configure and control the system through your PC

Pagina 12 - 2.4 Connecting EMD

Copyright Copyright© 2006 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribe

Pagina 13 - 2.6 Connecting LAN or WAN

4. The Properties window opens. Click” Restore Defaults” to use the default settings. Make sure that the Bits per second field is set to 9600. Clic

Pagina 14

6. After enter correct password, you will see the main menu of console interface. - 7 -

Pagina 15

5.2 IP Power Manager Configuration In this option. You can setup the general settings of this IP Power Manager. 5.2.1 System Group In this opt

Pagina 16 - Chapter 4 Quick Setup

5.2.2 Control Group - 9 - Option Description Administrator User Name In default, the user name is “admin”. You can change the user name to a simpl

Pagina 17

standard Telnet port (23). HTTP Control Enable/Disable the HTTP connection with the IP Power Manager. The user may configure HTTP protocol to use a p

Pagina 18

Power on Delay (Seconds) Set power on delay time in seconds. The outlet will turn on after the delay time. Power off Delay (Seconds) Set power off de

Pagina 19 - 5.1 Run Hyper Terminal

5.5 Trap Receiver Table This page lists the parameters for SNMP trap receivers (For SNMP Network Management). Option Description IP Address The IP

Pagina 20

5.6 Reset Configuration To Default When you would like to reset IP Power Manger to default configuration, please select this option and press “y”.

Pagina 21

5.8 Exit Select this option to exit Hyper Terminal. - 14 -

Pagina 22 - Option Description

Chapter 6 Web Configuration The IP Power Manager provides a graphic user interface that can be viewed from a web browser such as Internet Explorer.

Pagina 23 - 5.2.2 Control Group

Federal Communication Commission (FCC) Radiation Exposure Statement This equipment complies with FCC radiation exposure set forth for an uncontrolled

Pagina 24 - 5.3 Outlets Control

connected), System, Network and Logs. When you click the IP Power Manager front panel on the Home screen. You will see the device status as below.

Pagina 25 - 5.4 Access Control

6.1.1.1 Inlet This page shows the associated status and even action of inlet. - 17 - Option Description Status Input Voltage (Volt) The current i

Pagina 26 - 5.5 Trap Receiver Table

Input Voltage Threshold Low (Volt) Low threshold of input voltage. When input voltage is lower than this value, IP Power Manager will take action spe

Pagina 27

Power Off Delay (Seconds) Set power off delay time in seconds. The outlet will turn off after the delay time. Output Current Threshold (Amp) Set the

Pagina 28 - 5.8 Exit

Turn On / Turn Off button Turn digital outputs on or off manually. 6.1.2 Schedule This page allows user to add or remove the IP Power Manager's

Pagina 29 - Chapter 6 Web Configuration

Type" is "Special Schedule". Schedule Date (yyyy/mm/dd) Set the date of this schedule. Schedule Time (hh:mm) The time in 24-hour for

Pagina 30 - 6.1 Power Management

- 22 - Option Description Sensor Name Configure the name of a sensor (or device) with up to 15 characters.Set Point The threshold of a sensor (Te

Pagina 31

EMD Temperature Unit Choose the displayed temperature unit to “Celsius” or “Fahrenheit”. 6.2.3 Alarm This page allows user to modify the parameters

Pagina 32

Option Description Configure System System Name This field allows the user to set the value in System name that is defined in MIB-II or to view the

Pagina 33

Option Description Index This column provides a reference number for the existence user. User Name The user name which is used to log in the IP P

Pagina 34 - 6.1.2 Schedule

TABLE OF CONTENTS CHAPTER 1 INTRODUCTION...1 1.1 PACKAGE CONTENTS...

Pagina 35 - 6.2 Environment

6.3.3 Date & Time This page provides the appropriate options below to enable the IP Power Manager date/time to be changed in different methods.

Pagina 36

6.3.4 Trap Receivers This page lists the parameters for SNMP trap receivers (For SNMP Network Management). Option Description Index The index numb

Pagina 37 - 6.3 System

6.3.6 WOL IP Power Manager has support WOL function to wake your PCs up. This function can help your servers work again after the power interruption.

Pagina 38 - 6.3.2 Multi-User

6.3.7 Email Notification This page is allowed when the security level is “Administrator”. There are two groups in this page, one is “General Configur

Pagina 39

day in 24-hour format at which time you want the email sent. Email Receivers Tables Mail Account As Administrator, you may enter the email address of

Pagina 40 - 6.3.3 Date & Time

Option Description Screen Text This is the description of link name which will display on the menu tree for user's reference. Link Address Th

Pagina 41 - 6.3.4 Trap Receivers

Option Description IP Address The IP address of IP Power Manager is dotted format. Default value is "192.168.1.1", and size is 15 characte

Pagina 42 - 6.3.6 WOL

Telnet Connection parameter enabling or disabling the terminal to the server This is theapplication (Telnet) control process. (e.g. telnet 192.168.1

Pagina 43 - 6.3.7 Email Notification

Available options are: Permitted and Denied. Access Type .5 Logs e fundamental IP Power Manager parameters. The nsolidation interval by modifying th

Pagina 44 - 6.3.8 External Links

Option Description Date (dd/mm/yyyy) This column show the date on which the recording was made. Time (hh:mm:ss) This gives the time in a 24-hour for

Pagina 45 - 6.4 Network

CHAPTER 6 WEB CONFIGURATION...15 6.1 POWER MANAGEMENT...

Pagina 46 - 6.4.2 Control

Option Description Date (dd/mm/yyyy) This column show the date on which the recording was made. Time (hh:mm:ss) This gives the time in a 24-hour f

Pagina 47 - 6.4.3 Access Control

Chapter 7 Utility IP Power Manager has provided a utility for customer to set the IP address and upgrade. You can find this utility in “Utility” fold

Pagina 48 - .5 Logs

with the located firmware. Open Press this button to locate the firmware. Q- 38 - uit Close utility.

Pagina 49 - 6.5.2 Event

Appendix A Error Code E r Code rro Description E01 Network link down E02 Parameters checksum error E03 Input voltage over threshold high (Volt) E04

Pagina 50

Appendix B Specification Model IP IPM-8002-EU IPM-8002-UK M-8001-US LAN10 Port /100Mbps, RJ-45 Console port RJ-45 connector x 1 COM por1; For UPS co

Pagina 51 - Chapter 7 Utility

Appendix C Glossary A cation Authentication refe ed message's integrity. DDHCP (Dynamic Host Configuration Protocol) software automatically ass

Pagina 52

network. Every client and server station must haeither a permanent address or have one dyns four sets of numbers separated by periods (for example, m

Pagina 53 - Appendix A Error Code

- 43 - NMP hardware or software components transmit network device activity the workstation used to oversee the network. er or router and is compare

Pagina 54 - Appendix B Specification

Chapter 1 Introduction Thank you for purchasing PLANET IP Power Manager. This manual guides you on how to install and properly use the IP Power Manag

Pagina 55 - Appendix C Glossary

z Upgrade utility for easy firmware upgrade z Event notification through SNMP trap or E-Mail alerts z Daily history report through E-mail z Suppo

Pagina 56

LED Function Description 1 Current level indicator Displays the amount of current being drawn by the connected output device through the power out

Pagina 57

LED Function Description INPUT Input power consumption indicator Displays the amount of current being drawn by the connected output device through

Comentarios a estos manuales