4.1.3.3 SNMP Conguration
Get Community Name: to get the device community name (default = public).
Set Community Name: to set the device community name (default = private).
Trap Community Name: to authorize the device trap community name (default =
public).
Trap Host IP Address: to set the trap host IP address (same as monitoring station IP
address).
Cold Start trap: to set the trap for rebooting the device (default = enable).
Warm Start trap: to set the trap when the device had been reset (default = enable).
Authentication Fail Trap: to set the warning trap when the community name of the
device and workstation are different (default = enable).
Power Fail Trap: to set the Power Fail Trap (default = enable).
Fan Fail Trap: to set the fan fail trap (default = enable).
MC Plug-in Trap: to set the trap when a Media Converter module has been plugged in
(default = enable).
MC Pullout Trap: to set the trap when the Media Converter module has been pulled out
(default = enable).
MC Broken trap: to set the trap when the Media Converter module was broken (default
= enable).
MC Link up trap: to set the trap when a linking is connected (default = enable).
MC Link down trap: to set the trap when a linking is disconnected (default = enable).
MC Active Slot Xchg trap: to set the trap when there is a redundant function activated
(default = enable).
MC Active Slot Lose trap: to set the trap when the redundant function is fail (default
= enable).