User’s Manual ICS-100 / ICS-102 / ICS-102S15 RS-232/RS-422/RS-485 over 100Base-FX / 10/100Base-TX Media Converter
User’s Manual of ICS-10x -6- Dimension (W x D x H) 97 x 70 x 26mm Weight 200g Power Supply External Power Adaptor 5V DC / 2A max. Power Consumptio
User’s Manual of ICS-10x -7- 2. INSTALLATION This section describes the hardware features and installation of the ICS-10X’s components on the desktop
User’s Manual of ICS-10x -8- Figure 2-2 PLANET ICS-100 Front Panel ICS-102 / ICS-102S15 – RS-232 / RS-422 / RS-485 over 10/100Base-FX Figure 2-
User’s Manual of ICS-10x -9- 2.1.2 LED Indicators LED Color Function PWR Green Lights to indicate that the Converter is powered on. Lights To i
User’s Manual of ICS-10x -10- To press and release the RESET button. The ICS-10X will back to the factory default mode. Be sure that you backup the
User’s Manual of ICS-10x -11- Figure 2-7 ICS-102 / ICS-102S15 stand alone installation Please refers to APPENDIX-A for detailed wiring information
User’s Manual of ICS-10x -12- Step 4: After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack
User’s Manual of ICS-10x -13- 3. MANAGEMENT This chapter describes how to manage the ICS-10X. Topics include: - Overview - Management methods - Ass
User’s Manual of ICS-10x -14- 3.3 Management Methods The way to manage the ICS-10X: - Web Management via a network or dial-up connection 3.3.1 Web
User’s Manual of ICS-10x -15- Figure 3-2 Login screen 1. For security reason, please change and memorize the new password after this first setup.
User’s Manual of ICS-10x -2- Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is
User’s Manual of ICS-10x -16- 4. WEB CONFIGURATION The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configur
User’s Manual of ICS-10x -17- 4.2 System 4.2.1 System Information The System Information page provides information for the current device. System I
User’s Manual of ICS-10x -18- 4.2.2 Password Setting This function provides administrator to secure Web login. The screen in Figure 4-3 appears. F
User’s Manual of ICS-10x -19- 4.2.3 Firmware upgrade The Firmware Upgrade page contains fields for downloading system image files from the Local Fi
User’s Manual of ICS-10x -20- 4. Then the “Firmware Upgrade Mode” displayed as in Figure 4-6. Figure 4-6 Firmware Upgrade screen Click the “Browse”
User’s Manual of ICS-10x -21- 4.2.4 Factory Default The Factory Default can reset the ICS-10x back to the factory default mode. Be aware that the e
User’s Manual of ICS-10x -22- 4.3 Network Configuration This function allows setting the value for network configuration. The value is DHCP client,
User’s Manual of ICS-10x -23- When DHCP Client is set to Enable, the IP Address, Subnet Mask, Gateway and DNS fields are not allow to be changed. I
User’s Manual of ICS-10x -24- Other ICS-10x with TCP Client mode It opens the TCP port of ICS-10x to wait for serial application to establish a TCP
User’s Manual of ICS-10x -25- • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity
User’s Manual of ICS-10x -3- TABLE OF CONTENTS 1. INTRODUCTION ...
User’s Manual of ICS-10x -26- Figure 4-15 Example: Serial Port Configuration screen Hyper Terminal setup a new connection with TCP/IP Winsock 3.
User’s Manual of ICS-10x -27- 4. On the File menu, click New Connection. 5. In the Name box, type a name that describes the connection. 6. In the
User’s Manual of ICS-10x -28- Figure 4-19 Example: Hyper Terminal configuration Value Description Host address The address or name of the connect
User’s Manual of ICS-10x -29- 4.4.2 TCP Client mode When the ICS-10x be configured to TCP Client mode, it allows Serial device that connected to se
User’s Manual of ICS-10x -30- 4.4.3 UDP Client mode When the ICS-10x be configured to UDP Client mode, it allows Serial device that connected to se
User’s Manual of ICS-10x -31- The page includes the following fields: • Local UDP Port Enter the local port number • Remote Address Enter the IP addr
User’s Manual of ICS-10x -32- The page includes the following fields: • TCP Port Number The TCP port that ICS-10X uses to listen to connections and t
User’s Manual of ICS-10x -33- Figure 4-28 Example: Virtual COM Configuration screen 2. Set the Serial Port Configuration of ICS-10x as below: Mode
User’s Manual of ICS-10x -34- VCOM Utility to create virtual COM port 3. This mode will run with the software-“PLANET VCOM Utility”. Open the VCOM u
User’s Manual of ICS-10x -35- Hyper Terminal setup a new connection with virtual COM port 5. On the File menu, click New Connection. 6. In the Name
User’s Manual of ICS-10x -4- 4.5 SERIAL PORT CONFIGURATION ...
User’s Manual of ICS-10x -36- Figure 4-34 Example: HyperTerminal Com port properties screen 10. After the Virtual COM connection is established, o
User’s Manual of ICS-10x -37- Figure 4-36 Example: Hyper Terminal COM port screen 4.4.5 Telnet Server mode TELNET (TELecommunication NETwork) is
User’s Manual of ICS-10x -38- Figure 4-38 Telnet Server Configuration screen The page includes the following fields: • TCP Port Number The TCP port
User’s Manual of ICS-10x -39- Setup Operation Mode and Serial Port of ICS-10x 1. Set the ICS-10X mode to “Telnet server mode” from web interface. 2.
User’s Manual of ICS-10x -40- Figure 4-42 Example Windows Excuse - Telnet 7. To quit the Telnet session, press “CTRL+]” and then type “quit” Figu
User’s Manual of ICS-10x -41- Figure 4-44 Putty Configuration screen 8. Then can telnet IP address like to telnet switch’s IP. Figure 4-45 Putty
User’s Manual of ICS-10x -42- 4.4.6 Pair Connection– Local mode The parameter defines the maintenance status for listen for the pair connection. To
User’s Manual of ICS-10x -43- 4.4.7 Pair Connection – Remote mode The parameter defines the maintenance status for listen for the pair connection.
User’s Manual of ICS-10x -44- Example: Two ICS-10x with Pair Connection mode One be configured as Pair Connection – Local (Master) The other one be c
User’s Manual of ICS-10x -45- 1. Connect the converter with the IP camera for RS-485 interface like PLANET product: “ICA-651”. 2. Connect the conve
User’s Manual of ICS-10x -1- 1. INTRODUCTION Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Se
User’s Manual of ICS-10x -46- Figure 4-52 Pair Connection –Remote, operation mode configuration 6. Set the Serial Port mode of ICS-10x-Slave to R
User’s Manual of ICS-10x -47- 4.5 Serial Port Configuration The page shows the converter’s serial Port configuration. The screen in Figure 4-52 appea
User’s Manual of ICS-10x -48- contained in the serial buffer is paced in an Ethernet packet and sent out the Ethernet port. Silent Time: For the defi
User’s Manual of ICS-10x -49- 5. SOFTWARE VCOM UTILITY The ICS-10X Web Smart Media Converter provides software for Converter smart function configur
User’s Manual of ICS-10x -50- 3. The Installing window reports the progress of the installation. 4. Click Finish to complete Figure 5-3 VCOM install
User’s Manual of ICS-10x -51- 5.2 Search the Device Click the Search Device button to find the ICS-10X. It will show the ICS-10X device name, projec
User’s Manual of ICS-10x -52- Figure 5-6 VCOM Configuration 5. Then set the HyperTerminal parameter Figure 5-7 Hyper Terminal Configuration 6. th
User’s Manual of ICS-10x -53- Figure 5-8 VCOM Configuration 7. Once the Virtual COM Port- COM9 connection is established, from the Windows Device
User’s Manual of ICS-10x -54- APPENDIX A A.1 PLANET Smart Discovery Utility For easily list the ICS-10X in your Ethernet environment, the Planet Smar
User’s Manual of ICS-10x -55- 1. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version, De
User’s Manual of ICS-10x -2- 1.3 Product Description The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 /
User’s Manual of ICS-10x -56- A.4 RJ-45 cable pin assignment 2136 1 23 6 2 1 3 6 There are 8 wires on a standard UTP/STP cable and each wire is c
User’s Manual of ICS-10x -57- A.5 Fiber Optical Cable Connection Parameter The wiring details are as below: Fiber Optical patch Cables: (For ICS-
PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T
PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T
User’s Manual of ICS-10x -3- Process Control To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Pr
User’s Manual of ICS-10x -4- Surveillance motion control – Pair Connection Mode Using pair connection along with fiber optical patch cord, the ICS-1
User’s Manual of ICS-10x -5- ¾ Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500) LED indicators for easy network diagnose Reset